Test Equipment
- Analyzers »
- Generators »
- Meters »
- Oscilloscopes »
- Power Supply »
- Other »
- AC Power Source
- Amplifiers
- Attenuators
- Bit Error Rate Testers
- Cable Analyzers
- Cables
- Calibrators
- Coaxial Detectors
- Communication Equipment
- Current Preamplifier
- Curve Tracer
- Data Acquisition
- Directional Bridge
- Electronic Load
- Frequency Counters
- Lock-in Amplifiers
- Optical
- Power Loggers
- Probes
N2752A - Keysight (Agilent) Probe
- Model: N2752A
- Manufactured by: Keysight / Agilent Technologies
Keysight Agilent N2752A InfiniiMode Active Differential Probe, 6 GHz
Specifications:
Bandwidth: 6 GHz
Attenuation ratio: 2:1 or 10:1 (switchable)
Range:
Dynamic range: ± 5 V or 10 Vpp (at 10:1), ± 1 V or 2 Vpp (at 2:1)
DC offset range: ± 15 V
Maximum input voltage: 30 V DC + peak AC
Input Impedance:
Differential input R: 200 kΩ
Single-ended input R: 100 kΩ
Common mode input R: 50 kΩ
Input C: 700 fF (with browser)
Description:
The N2752A InfiniiMode differential probe is a new generation of low-cost differential active probes compatible with Keysight InfiniiVision and Infiniium oscilloscopes’ AutoProbe interface. It comes with new operation modes and convenient measurements of differential, single-ended, and common mode signals with a single probe tip, without reconnecting the probe to change the connection. The N2752A probe’s InfiniiMode provides the following modes of operation.
A – B (differential)
A – ground (single-ended A)
B – ground (single-ended B)
(A+B)/2 – ground (common mode)
Specifications:
Bandwidth: 6 GHz
Attenuation ratio: 2:1 or 10:1 (switchable)
Range:
Dynamic range: ± 5 V or 10 Vpp (at 10:1), ± 1 V or 2 Vpp (at 2:1)
DC offset range: ± 15 V
Maximum input voltage: 30 V DC + peak AC
Input Impedance:
Differential input R: 200 kΩ
Single-ended input R: 100 kΩ
Common mode input R: 50 kΩ
Input C: 700 fF (with browser)
Description:
The N2752A InfiniiMode differential probe is a new generation of low-cost differential active probes compatible with Keysight InfiniiVision and Infiniium oscilloscopes’ AutoProbe interface. It comes with new operation modes and convenient measurements of differential, single-ended, and common mode signals with a single probe tip, without reconnecting the probe to change the connection. The N2752A probe’s InfiniiMode provides the following modes of operation.
A – B (differential)
A – ground (single-ended A)
B – ground (single-ended B)
(A+B)/2 – ground (common mode)
Your IP Address is: 216.73.216.190
Copyright © 2025 RFTE Solutions